How to Choose Valves For the Chemical Industry

There are 4 key points to consider when selecting an industrial valve for the chemical industry
Table of Contents
    Add a header to begin generating the table of contents
    chemical industry

    Chemical valve selection requires special consideration of the scientific nature of the valve material. Usually, there is a misunderstanding that stainless steel is a “universal material”, regardless of what media and environmental conditions are using stainless steel valves, which is incorrect. In the following sections, we will analyze the selection of materials for common chemical media and other factors to match a valve to the chemical processing.

    Valve Material Selection

    Valve for Sulfuric Acid 

    lined pfa ball valve
    lined pfa ball valve
    lined ptfe butterfly valves
    lined ptfe butterfly valves

    As one of the strong corrosive media, sulfuric acid is a very wide range of important industrial raw materials. Different concentrations and temperatures of sulfuric acid have varying effects on the corrosion of materials. For concentrations above 80%, the temperature is less than 80 ℃ of concentrated sulfuric acid, it is a high-speed flow of sulfuric acid, carbon steel and cast iron are not suitable as valve materials, ordinary stainless steel such as 304 (0Cr18Ni9), 316 (0Cr18Ni12Mo2Ti) on the sulfuric acid medium corrosion resistance is also very limited. Therefore, industrial valves for conveying sulfuric acid are usually made of high silicon cast iron (but casting and processing are very difficult), and high alloy stainless steel (#20 alloy). The most reliable is to choose valves lined with fluorine material, because fluorine plastic has better resistance to sulfuric acid, and compared with high alloy stainless steel, fluorine lined valves are a more economical choice.

    lined control valves
    lined control valves-THINKTANK

    Valve for Hydrochloric Acid

    Most metallic materials are not resistant to hydrochloric acid corrosion (including various stainless steel materials), and molybdenum-containing high-silicon iron can only be used for 50 ℃, 30% below hydrochloric acid. Contrary to metal materials, most non-metallic materials have good corrosion resistance to hydrochloric acid, so rubber-lined valves and plastic valves (such as polypropylene, fluorine plastic, etc.) are a better choice for conveying hydrochloric acid.

    upvc pneumatic plastic butterfly valves
    upvc pneumatic plastic butterfly valves
    pneumatic 3 way plastic ball valves
    pneumatic 3 way plastic ball valves

    Valve for Nitric Acid

    General metal materials in nitric acid will be rapidly corroded and destroyed, stainless steel in nitric acid-resistant materials has a wide range of applications. In different concentrations of nitric acid at room temperature, stainless steel has good corrosion resistance. Please note that the corrosion resistance of molybdenum-containing stainless steels (such as 316, 316L) to nitric acid is not only worse than that of ordinary stainless steels (such as 304, 321), but the performance is even inferior to that of stainless steels without molybdenum such as 304. And for high-temperature nitric acid, titanium and titanium alloy materials are usually required.

    Valve for Acetic acid

    Acetic acid is one of the organic acid corrosive substances, ordinary steel in different concentrations and temperatures of acetic acid will be serious corrosion, stainless steel is excellent acetic acid-resistant material, molybdenum-containing 316 stainless steel can also be applied to high temperature and dilute acetic acid vapor. For high temperature and highly concentrated acetic acid or containing other corrosive media and other demanding requirements, high alloy stainless steel valves or fluorine plastic valves can be used.

    lined pfa ball valve dimension
    lined pfa ball valve dimension

    Chemical processes require valves to handle a variety of functions related to various liquids and gases, such as opening or closing flow, controlling flow rates, preventing backflow or backflow, and regulating pressure or relieving pressure.
    Valves can also be classified as linear or rotary depending on the movement of the closing components, such as globe valves (linear) and butterfly valves (rotary).
    Valves can be classified according to the shape of their closing parts, such as gate valves, globe valves, plug valves, diaphragm valves, or butterfly valves.
    Depending on the application and pressure and temperature conditions, such as the need for fire-resistant valves. Some valves only require manual actuation. Power actuators are used if the valve is located far from the mechanism, needs a frequent operation, or must automatically respond to the dynamic parameters of the control system, such as adjustment of flow, temperature, or pressure.

    Valve Parts

    Valve Body

    The valve body houses all the internal working parts of the valve and includes the flange. Inside the valve body, the shutoff element moves to adjust the flow of fluid through the valve. To shut off the fluid, the mating surface of the shutoff element is pressed against the valve seat to achieve a tight shutoff. The seat is usually attached to the valve body, and most valves have a metal closure element that seals against a flexible, resilient seat. Sometimes the seat may also be metal, which is selected depending on the service conditions. The distance that the closure element travels from fully open to fully closed is called the valve stroke.

    Valve Stem

    The stem is the part that connects the valve’s actuator to the closing element. The stem can pass through the bonnet (protected from leakage by the stem packing box) and then connect the closing element for movement. However, many valves (such as rotary plugs and some ball designs) do not have a bonnet.

    Bonnet

    Bonnets are usually screwed or bolted semi-permanently to the valve body. Different valves have different bonnet designs. The bonnet usually needs to be removed if routine maintenance or servicing is required.

    Packing Box

    The packing box is the internal area between the valve stem and the bonnet that contains the packing that seals the stem to prevent leakage to the outside of the valve. The packing nut on the bonnet is usually used to compress the packing.

    In many valve designs, the bonnet has a back seat to seal the stem to avoid leakage into the packing when the valve is in the fully open position. A bushing on the stem provides the mating surface. The back seat also prevents the stem from ejecting from the valve if the packing begins to leak.

    Different fluid characteristics can also affect valve operation. For example, the lubricity of the fluid will determine the actual operating torque of the valve. Gases usually do not require lubrication to be considered. In particular, fluids carrying solids can clog the moving gap between the stem and other components, thus greatly increasing the torque required, sometimes by twice or more than a clean fluid. Over time, rusted internal parts can also increase resistance, so we need to maintain the valve on a regular basis to ensure consistent operating performance.

    For fire safety, some valves need to be designed with resilient metal seats so that even if the valve’s first soft seal is melted in a fire, the valve’s second metal seat can still compensate for the seal and keep the valve closed properly. In addition, in consideration of fail-safe operation, the actuator and valve accessories need to be selected to meet the need to keep the valve in a safe position in the event of loss of power or air supply.

    Actuator Selection

    The power source of the valve actuator should have a sufficient safety margin over the required torque. The operating torque of a valve depends on valve size, pressure rating, valve characteristics, and the type of seat. Valves operating at full rated pressure typically require more torque than valves at lower pressures.

    In general, the actual maximum torque plus an appropriate safety margin is used when selecting an actuator for on/off. For valves that require a quarter turn, calculating torque is often more complicated because additional torque is required to balance the turbulent flow of the fluid. For smooth operation, the torque output of the actuator should greatly exceed the operating torque.

    Torque calculations are usually performed at ambient temperatures and require greater operating torque at high and low temperatures. Fluid temperatures above 140°C may require a special operating and mounting assembly, usually stem design extension type. Even in normal environmental conditions, actuators located outdoors may require special consideration.

    Another important consideration is the cycling rate. For electric actuators, if the cycling frequency exceeds 10% of their duty cycle, an extended duty motor is required. Otherwise, the rapid cycling rate can damage the valve and actuator components. Pneumatic and hydraulic actuators are also considered to have a high operating rate when cycling more than 30 times per hour. Pneumatic actuators can increase torque by adding a quick exhaust valve, increasing the size of the air source tube pipeline, or a larger actuator size.

    One easily overlooked but important consideration in piping design systems is the direction of the valve stem. Stem misalignment can lead to stem seal leakage or galling due to side thrust caused by overhanging loads on the actuator. The use of heavy-duty couplings and mounting brackets can minimize these problems.

    667 Actuator With Cv3000 Globe Control Valve
    single spring diaphragm actuator
    linear type pneumatic actuator
    linear type pneumatic actuator
    rotary type pneumatic actuator
    rotary type pneumatic actuator

    Pneumatic actuators are used in a wide variety of valves and are particularly well suited for service conditions requiring frequent operation and fast response. Depending on the system selected, these pneumatic actuated valves typically operate in the 2-10 bar range, with 4-6 bar air power being the most common. The compressed air supply is typically provided by an instrument air compressor package to ensure clean and dry air. There are two types of pneumatic actuators: piston type and diaphragm type. The piston type pneumatic actuator can have a long stroke, suitable for large size valves and its torque is relatively high compared to the diaphragm type. Most pneumatic piston type actuators will be used for valves that are operated on and off.

    Diaphragm pneumatic actuators are usually suitable for regulating services, such as installation on control valves such as globe valves, eccentric plug valves, v-notch ball valves, butterfly valves, etc. However, their short stroke limits the size of valves that can be used. Pneumatic actuators are relatively large and require frequent maintenance because air can leak over time (especially with piston types), and diaphragm pneumatic types can suffer from diaphragm deterioration, among other problems.

    control valve specifications
    control valve supplier in china

    Electric actuators are also often selected for valve operation, especially in power stations, where the use of electric valves tends to have the lowest total installed cost because field power is usually readily available and wiring and control instrumentation are relatively simple. However, with electric actuators that increase torque through large gear reducers, the response and action of the valve are often unwieldy and slow. Also, considering that power outages or electrical system failures are possible, we need to design an emergency plan for electric valves to ensure that the valves are safe in the event of a failure.

    Hydraulic actuators are applied in less working conditions, but they are preferred for some special valves. Especially large size valves with high pressure which need frequent cyclic action to generate huge torque by hydraulic oil.

    Valve Rating

    The pressure rating of a valve indicates the ability of the valve to withstand pressure within a certain temperature range. The standard pressure ratings are well established, and we can refer to ratings in accordance with ASME/ANSI B16.34. The pressure rating is followed by the designation “WSP” for working steam pressure, and “WOG” for water, oil & gas. If a valve is used primarily for water service, a common designation is “WWP” or Water Working Pressure, indicating the ability to handle cold water.

    2000wog ball valve supplier 1
    2000wog ball valve supplier

    For example, 1000 WOG means 1000 psi pressure rating for water, oil, and gas. Class 300LB indicates a valve with a nominal pressure of 300 psig.

    High temperature or high pressure service can cause a valve to have a lower pressure rating, and most industrial valves have temperature limits based on the capacity of the seat and trim material. Material selection is generally made by the working temperature but not pressure drop, so the suitability of the material is primarily based on temperature.

    In some cases, the pressure drop must be kept to a minimum, and precise determination of the pressure drop through the valve is also necessary for the valve selection. Usually, we use the valve flow rate to measure the standard, the rated flow factor “Cv”, which indicates the flow rate through the valve at the maximum opening for a given pressure drop. Valve manufacturers usually determine this coefficient value by actual flow testing.

    In Conclusion

    When selecting chemical valves, the first factor to understand the chemical properties of the medium, and then the factors to consider are temperature and pressure. The properties, concentration, and temperature of the fluid are critical to the selection of corrosion-resistant materials. The valve body, plug, and operating components should be able to withstand the highest temperatures under continuous normal and transient operating conditions, as well as withstand the highest transient pressures expected. The final consideration is the degree to which the valve will shut off and should meet the field requirements for leakage. Manufacturers perform a bubble seal test before the valve leaves the factory, by testing the resilient seat of the valve for significant leakage. Other key parameters include flow speed, valve function (on/off or modulating), whether fire safety is required, and other additional functional requirements. Hope this article can help you a little about valve selection during chemical processing. Meanwhile if you are interested in more information about different types of control valves, you can read this article.

    Facebook
    Twitter
    LinkedIn
    Pinterest
    Print
    Picture of Will Don

    Will Don

    After earning my bachelor's degree in mechanical engineering from Zhejiang Normal University in 2008, l was fortunate enough to begin my career with Siemens, Fisher, and YTC, focusing on control valve accessories. Over the past dozen years, l've poured my heart and energy into understanding technology and fluid solutions for control valves.
    Now, as the marketing director for THINKTANK, a trusted branch of the Taiwan STONE valve group, I can't help butf eel proud of how far we've come. Our knowledge isn't just reaching professionals like engineer and valve distributors; it's also inspiring the next generation of automation college students.
    l genuinely hope you're enjoying our articles and finding them helpful.Your thoughts, questions, and feedback mean the world to me, so please don't hesitate to reach out to marketing[at]cncontrolvalve.com. Whether you're a seasoned expert or just curious about the field, I'm here to connect, share, and learn together.

    All Posts »

    I am the author of this article, and also the CEO and marketing director of THINKTANK, with 15 years of experience in the industrial valve industry. If you have any questions, you can contact me at any time.

    Subscribe Now

    Receive the latest product information and industry news.

    We value your privacy. Your information will be kept confidential.

    Contact Us

    Just fill out your name, email address, and a brief description of your inquiry in this form. We will contact you within 24 hours.

    The Latest News
    3 functional pressure vacuum valve

    3-Function Pressure Vacuum Valve

    The 3-Function Pressure Vacuum Valve improves on the basic functionality of an air vent head by adding a nitrogen gas preservation feature. It opens at ...
    Read More
    spring return electric actuated ball valve fail safe

    Spring Return Electric Actuator: Technical Principles, Applications and Common Valve Types

    The Spring Return Electric Actuator is a critical device for ensuring safety in high-risk environments such as tunnels, subways, marine applications, and other areas where ...
    Read More
    pilot operated breather valve

    Case Study: How to Select a Suitable Breather Valve to Handle Back Pressure

    In industrial storage tank applications, it is critical to select the right pressure and vacuum relief valves (PVRV) to ensure the safe operation of the ...
    Read More
    axial piston high pressure pump

    High Pressure Pumps Axial Piston Pumps

    In the past 5 years, we made our HPR/HPH series axial piston pumps as OEM products for a well-known brand. These pumps have been successful ...
    Read More
    breaker valve manufacturer

    VB14 and VB21 Vacuum Breaker Installation

    VB14 Vacuum Breaker Description VB14 is a small special vacuum breakers used in condensing vapour/steam or liquid systems, and it made of Brass material, and ...
    Read More
    common valve abbreviation guide

    Common Valve Abbreviation Guide

    In industrial manufacturing and instrument maintenance, you’ll see many abbreviations for valves. It’s important for engineers, maintenance people, and students to know these abbreviations because ...
    Read More
    spray & fuse coating

    Comprehensive Technical Guide on Hard Coating For Severe Service Valve

    One of the most effective ways to improve the durability and performance of valves in in severe service environments, where valves are work at extreme ...
    Read More
    dosing valve DN100 lime dosing system

    What is a Lime Dosing Valve and How Does It Work

    In the world of water treatment and chemical processing, it’s important to control lime dosing accurately. Getting the pH right and avoiding lime blockages can ...
    Read More
    concentrated solar power schematic

    Selection and Application of Molten Salt Control Valves

    In recent years, as the environmental impact of traditional energy sources such as coal and petrochemicals has become more and more of a concern, there ...
    Read More

    Contact Us

    With expertise in valves and rich experience in the oil&gas, chemical industry, textile mills, power plants, and sugar mills. THINKTANK has become the premier manufacturer of next-generation precision control valves.

    With a customer base that includes over 42 of the world’s leading engineering&contractors and international valve brands, THINKTANK Valves offers cost-effective valves that help our customers achieve automated process control without paying high prices.

    Why are more and more international valve brands choosing THINKTANK for OEM service?

    Brand is reputation, which not only requires high valve technology, but also great comercial support and fast response after-sales service and delivery time. They will not gamble their brand on an unknown product

    Get an Instant Quote

    Avoid your inquiry is delay response, please enter your WhatsApp/Wechat/Skype along with the message, so we can contact you at the very first time.

    We will reply you within 24 hours. If for urgent case, please add WhatsApp: +86 185 1656 9221, or WeChat: +86 199 2125 0077. Or call +86 189 5813 8289 directly. 

    Get An Instant Quote

    Joy Preview

    Get An Instant Quote

    We will reply you within 24 hours. If for urgent case, please add WhatsApp: +86 199 2125 0077, or WeChat: +86 199 2125 0077. Or call +86 189 5813 8289 directly. 

    Direct to Control Valve Factory With Competitive Price & Reliable Quality

    Joy Preview
    Joy Preview

    Get An Instant Quote

    Just leave your name, email, and simple message or requirements, We will contact you within 1 hour.

    WhatsApp: +86 199 2125 0077

    Skype ID: sowell85

    Wechat ID: +86 199 2125 0077