Refining Industry: Hydrogenation, Delayed Coking, Catalyst Regeneration, Reforming, Sulfur Recovery

Related Products: Mid, High-Pressure Control Valve, High-Pressure Angle Valve, High-Pressure Parallel Gate Valve, Double Eccentric High-Performance Butterfly Valve, Triple Eccentric High-Performance Butterfly Valve, Eccentric Rotary Valve

REFINING

The refining industry has undergone many changes, from the methods of processing to the length of time that they operate their process units. These changes, along with the emergence of low sulfur fuel specifications, the requirement to process lower grade crude and the need to convert more bottom-of-the-barrel residuals, has put an extreme demand on isolation and control valves. Unreliable and unpredictable valves in emergency situations can cause enormous monetary losses and have devastating consequences for personnel. THINKTANK has responded to these challenges by developing a combination of diverse trim configurations and high quality coatings for use in high temperature, high pressure, erosive, corrosive, viscous and coking/asphaltene applications.

Reference List

  • Air preheater of 10 million tons of atmospheric and vacuum furnace soot blowing device of Petrochemical.
  • 2.5 million tons of atmospheric and vacuum air preheater soot blowing device of Tianjin Petrochemical.
  • 3.2 million tons of diesel hydrogenation plant of Tianjin Petrochemical.
  • 10 million tons of atmospheric and vacuum air preheater of Tianjin Petrochemical Soot blowing device.
  • Tianjin Petrochemical 1.8 million tons of hydrocracking/1.3 million tons of wax oil hydrogenation.
  • Shengli Oilfield Petrochemical Project.

Case Study

Project Name: Refinery Industry 20000Nm3/h Hydrogen Production Project

Project Date: May, 2013

Project Location: Shaanxi Province, China

The information of end-user:

Yulin Oil Refinery is located in the eastern suburbs of Jingbian County, Shaanxi Province, and was founded in 1993. In the initial stage of plant construction, the plant’s scale is only 150,000 tons/year of crude oil processing capacity and 70,000 tons/year of secondary processing capacity. Through more than ten years of development, the current installation’s primary crude oil processing capacity is 2 million tons/year, and the secondary processing capacity is 800,000 tons/year.

Problem: 

Yulin Oil Refinery mainly processes crude oil in the Yulin area. It is estimated that the crude oil output in 2014 will be close to 5 million tons/year, which exceeds the refinery’s processing capacity. Therefore, the entire 5 million tons/year crude oil processing and supporting system transformation must be implemented as soon as possible to meet the rising demand for crude oil production in the Yulin area. And to cooperate with the country’s gasoline and diesel product upgrades, a 20,000Nm3/h hydrogen production device was designed in a combined device of 900,000 tons of gasoline and 2 million tons of diesel to ensure gasoline and diesel indicators meet the national level IV standards.

Design:

The design of the hydrogen production unit in the combined plant. This hydrogen production unit is designed for a reformed gas hydrogen extraction unit with 13000Nm3/h qualified hydrogen, with a design load of 60%~110%, and a conversion hydrogen production unit with a scale of 20000Nm3/h qualified hydrogen with a design load of 40%~110%.

Solution: 

THINKTANK has provided 92 control valves for this device, used for raw gas pretreatment, conversion and medium temperature conversion, medium variable gas heat exchange and cooling, acid water recovery system, and PSA hydrogen purification unit. The products range includes globe type control valves, ball valves, high-performance butterfly valves, gate valves, etc.

handwheel mechanism must be tested after valve maintenance

Handwheel Mechanism Must Be Tested After Valve Maintenance

— From the Perspective of THINKTANK Control Valve Engineers Why handwheel mechanisms still matter in modern chemical plants In chemical plants, many control valves operate continuously for long periods and cannot be isolated for maintenance. When a remote control failure occurs, the handwheel mechanism often becomes the only way to

Read More »
mechanical stops

Mechanical Stops Not Reinstalled After Maintenance

— From the Perspective of THINKTANK Control Valve Engineers Why mechanical stops are safety devices, not optional accessories In many plants, mechanical stops on control valves are treated as secondary hardware. From our engineering perspective at THINKTANK, this is a serious misunderstanding. A mechanical stop serves two critical purposes: A

Read More »
Installation & Commissioning as a Failure Source in Control Valve Performance

Control Valve Loop Check Consistency

— From the Perspective of THINKTANK Control Valve Engineers Why loop check problems are rarely noticed — until a trip happens In most projects, control valve loop checking is treated as a routine task. The controller output is changed.The valve moves.The position feedback looks reasonable. The loop is marked as

Read More »
control valve calibration

Control Valve Positioner Error and Deadband Issues

— From the Perspective of THINKTANK Control Valve Engineers Why we never accept “stroke test passed” as final acceptance In many chemical plants, valve commissioning ends once a control valve passes a basic stroke test. Typical checks include: If the valve reaches all five points correctly, it is often considered

Read More »
duplex 2205 control valve

Air Lock Valve Trip Setting Errors

— From the Perspective of THINKTANK Control Valve Engineers Why we treat air lock valve trip setting as a critical control parameter In chemical plants, air lock valves are often regarded as secondary pneumatic accessories.In reality, from our engineering experience at THINKTANK, the air lock valve trip setting is a

Read More »
solenoid valve logic errors

Solenoid Valve Logic Errors in Control Valve Interlocks

— From the Perspective of THINKTANK Control Valve Engineers Why we always separate “fail position” from “interlock action” When customers report that a control valve moved in the wrong direction during an interlock, the first thing we clarify is this: Solenoid valve action and control valve fail position are two

Read More »

Get an Instant Quote

Avoid your inquiry is delay response, please enter your WhatsApp/Wechat/Skype along with the message, so we can contact you at the very first time.

We will reply you within 24 hours. If for urgent case, please add WhatsApp: +86 185 1656 9221, or WeChat: +86 199 2125 0077. or call +86 189 5813 8289 directly. 

Get An Instant Quote

Joy Preview

Get An Instant Quote

We will reply you within 24 hours. If for urgent case, please add WhatsApp: +86 199 2125 0077, or WeChat: +86 199 2125 0077. Or call +86 189 5813 8289 directly. 

Direct to Control Valve Factory With Competitive Price & Reliable Quality

Joy Preview
Joy Preview

Get An Instant Quote

Just leave your name, email, and simple message or requirements, We will contact you within 1 hour.

WhatsApp: +86 199 2125 0077

Skype ID: sowell85

Wechat ID: +86 199 2125 0077