Motorized Globe Control Valve DN200

Search Related Products

Motorized Globe Control Valve DN200

Electric control valves are critical components in industrial automation, extensively used across various sectors including oil, chemicals, power generation, and pharmaceuticals. THINKTANK experts offer detailed guidance on model parameters and operational condition selection to assist you in choosing and utilizing the best electric control valves for your needs.

Additional information

Size:

1'' ~ 24''

ANSI Class:

150 ~ 2500LB

Body Materials:

A216 WCB, A216WC6, A352 LCB, A351 CF8, A351 CF8M, A351 CF3M, A351 CF3

Temperature Range:

-196 ~ +550°C

Description

Electric Globe Control Valves: Essential for Industrial Automation

Product Name: Electric Globe Control Valve

Design Standard: ANSI/ISA 75.01.01 & ASME B16.34
Face to Face Standard: ASME B16.10
Flange Standard: ASME B16.5

Electric control valves are critical components in industrial automation, extensively used across various sectors including oil, chemicals, power generation, and pharmaceuticals. THINKTANK experts offer detailed guidance on model parameters and operational condition selection to assist you in choosing and utilizing the best electric control valves for your needs.

electric globe control valve
electric globe control valve

Model Parameters of Electric Control Valves

Model Description

The model number of an electric control valve typically comprises letters and numbers, indicating the manufacturer, function, connection type, and drive mode. For instance, the model “TT-EHCB/100C” signifies a THINKTANK brand electric control valve, where ‘E’ stands for Electric, ‘HCB’ denotes a control valve series, ‘100’ indicates a nominal diameter of DN100mm, and ‘C’ specifies the use of Carbon Steel in the valve body.

flow characteristics of control valve pressure
flow characteristics of control valve pressure

Temperature & Pressure Range of Body Material

Temperature ℃ Class150 Class300 Class600
LCB WCB
A105
WC6
F11
F304
CF8
F316
CF8M
LCB WCB
A105
WC6
F11
F304
CF8
F316
CF8M
LCB WCB
A105
WC6
F11
F304
CF8
F316
CF8M
-196~38 1.90 1.90 4.95 4.95 9.91 9.92
-45~38 1.84 1.90 1.90 4.78 4.95 4.95 9.57 9.91 9.92
-5~38 1.84 1.96 1.99 1.90 1.90 4.78 5.10 5.16 4.95 4.95 9.57 10.2 10.32 9.91 9.92
~50 1.81 1.92 1.92 1.84 1.84 4.72 5.00 5.16 4.77 4.80 9.46 10.1 10.32 9.56 9.62
~100 1.72 1.76 1.76 1.56 1.61 4.51 4.63 5.14 4.08 4.21 9.02 9.27 10.29 8.17 8.43
~150 1.57 1.57 1.57 1.39 1.47 4.40 4.51 5.01 3.62 3.85 8.78 9.04 10.03 7.26 7.69
~200 1.40 1.40 1.40 1.25 1.37 4.26 4.38 4.88 3.27 3.56 8.54 8.75 9.75 6.54 7.12
~250 1.20 1.20 1.20 1.16 1.20 4.05 4.16 4.62 3.04 3.34 8.11 8.33 9.26 6.10 6.67
~300 1.01 1.01 1.01 1.01 1.01 3.76 3.87 4.23 2.91 3.15 7.54 7.74 8.48 5.80 6.32
~350 0.84 0.84 0.84 0.84 0.84 3.59 3.69 4.01 2.81 3.03 7.18 7.38 8.04 5.60 6.07
~375 0.73 0.73 0.73 0.73 3.64 3.88 2.77 2.96 7.28 7.75 5.54 5.93
~400 0.64 0.64 0.64 0.64 3.44 3.65 2.74 2.91 6.89 7.31 5.48 5.81
~425 0.55 0.55 0.55 0.55 2.88 3.44 2.71 2.87 5.74 6.91 5.42 5.72
~450 0.47 0.47 0.47 0.47 1.99 3.08 2.68 2.81 4.00 6.17 5.37 5.61
~475 0.37 0.37 0.37 0.37 1.35 2.58 2.65 2.73 2.70 5.17 5.30 5.46
~500 0.28 0.28 0.28 0.28 0.88 2.02 2.60 2.67 1.75 4.04 5.20 5.37
~525 0.18 0.18 0.18 0.18 0.51 1.53 2.19 2.57 1.03 3.07 4.77 5.15
~550 1.20 2.00 2.40 2.40 4.00 4.60
~566 1.00 1.90 2.20 2.00 3.80 4.50
Temperature℃ Class900 Class1500 Class2500
LCB WCB
A105
WC6
F11
F304
CF8
  F316
CF8M
LCB WCB
A105
WC6
F11
F304
CF8
   F316
CF8M
LCB WCB
A105
WC6
F11
F304
CF8
   F316
CF8M
– 196~38 14.88   14.88 24.79    24.79 41.34    41.34
-45~38 14.35 14.88   14.88 23.92 24.79    24.79 39.87 41.34    41.34
-5~38 14.35 15.31 15.50 14.88   14.88 23.92 25.51 25.84 24.79    24.79 39.87 42.52 43.07 41.34    41.34
~50 14.18 15.01 15.33 14.34   14.43 23.64 25.02 25.55 23.90    24.04 39.40 41.70 42.59 39.84    40.07
~100 13.52 13.90 14.62 12.25   12.65 22.53 23.16 24.36 20.42    21.09 37.56 38.62 40.61 34.01    35.14
~ 150 13.18 13.56 13.90 10.89   11.54 21.96 22.60 23.18 18.16    19.24 36.60 37.66 38.61 30.26    32.07
~200 12.79 13.14 13.63 9.82   10.69 21.32 21.89 22.73 16.37    17.83 35.53 36.50 37.88 27.28    29.71
~250 12.17 12.51 13.33 9.15   10.02 20.28 20.84 22.22 15.26    16.68 33.80 34.75 37.03 25.43    27.80
~300 11.30 11.61 12.72 8.71   9.49 18.84 19.36 21.20 14.52    15.80 31.40 32.26 35.33 24.20    26.34
~350 10.78 11.08 12.06 8.42   9.12 17.96 18.46 20.11 14.02    15.20 29.95 30.78 33.51 23.36    25.36
~375 10.94 11.63 8.32   8.91 18.22 19.38 13.86    14.84 30.37 32.32 23.12    24.74
~400 10.34 10.98 8.23   8.72 17.24 18.28 13.72    14.55 28.73 30.47 22.87    24.25
~425 8.62 10.53 8.14   8.59 14.37 17.54 13.57    14.32 23.94 29.23 22.63    23.87
~450 6.01 10.13 8.06   8.42 10.02 16.89 13.42    14.03 16.68 28.16 22.37    22.79
~475 4.06 9.50 7.97   8.20 6.76 15.82 13.27    13.67 11.28 26.36 22.13    22.34
~500 8.33 7.81   8.05 13.89 13.02    13.40 23.15 21.71    21.47
~525 6.08 7.15   7.73 10.12 11.94    12.89 16.88 19.88    20.79
~550 3.83 6.54   7.49 6.38 10.91    12.48 10.63 18.17    17.85
~575 2.55 6.02   7.22 4.24 10.04    12.04 7.08 16.72    15.20
   ~600     –     – 1.75 5.01    6.43    –      – 2.94 8.35   10.71     –     – 7.90 13.92    17.85
   ~625     –     – 3.92    5.48    –      – 6.54   9.12     –     – 10.89    15.20
   ~650     –     – 3.16    4.23    –      – 5.25   7.06     –     – 8.75    11.76
   ~675     –     – 2.33    3.78    –      – 3.88   6.31     –     – 6.45    10.53

Key Parameters

  • Main parameters include nominal diameter, flow coefficient, adjustable range, drive mode, power supply voltage, and protection grade:
  • Nominal Diameter: This is the inlet and outlet diameter of the electric control valve, determining its flow capacity. Choose a suitable nominal diameter based on actual needs.
  • Flow Coefficient: A measure of the valve’s flow capacity, which is related to the nominal diameter. A higher flow coefficient indicates a stronger flow capacity.
  • Adjustable Range: An important performance index of the valve, indicating the range of flow it can control within its rated stroke. A larger adjustable range means broader control capabilities.
  • Drive Mode: Includes mechanical electric, smart, or digital electric actuator. Select based on actual needs and site conditions.
  • Power Supply Voltage: Common voltages include AC220V, 380V, or DC24V. Consider site power conditions when choosing.
  • Protection Grade: Indicates the valve’s dust and water resistance, essential for suitability in harsh environments.

Cv Rate and Valve Travel

Class150~600, PN16~110

Size 32 40 50 65 80 100 125
Seat 32 40 50 65 80 100 125
Rated
Cv
EQ% 11 17 11 17 24 17 24 44 24 44 68 44 68 99 68 99 175 99
Linear% 11 17 11 17 24 17 24 44 24 44 68 44 68 99 68 99 175 99
Travel(mm) 25 38 50

 

Size 125 150 200 250 300 350 400 450 500 600
Seat 125 150 200 250 300 350 400 450 500 600
Rated
Cv
EQ% 175 275 175 275 360 275 360 650 1050 1200 1700 1800 2500 3540 4180 4650 5850
Linear% 175 275 175 275 360 275 360 650 1350 1560 2120 2750 3300 4650 5500 5850 6700
Travel(mm) 50 75 100 120 150 200 280

Class900~ 1500, PN150~260

Size 32 40 50 65 80 100
Seat 32 40 50 65 80 100
Rated
Cv
EQ% 12 17 12 17 25 17 25 50 25 50 80 50 80 110 80 110
Linear% 12 20 12 20 30 20 30 60 30 60 90 60 90 140 90 140
Travel(mm) 25 38

Size 100 125 150 200 250 300 350 400 450
Seat 100 125 150 200 250 300 350 400 450
Rated
Cv
EQ% 180 110 180 275 180 275 360 275 360 650 1000 1440 2040 2500 3100
Linear% 200 140 200 330 200 330 480 330 480 700 1050 1500 2040 2650
Travel(mm) 38 50 75 100 120 175

Class2500

Size 32 40 50 65 80 100 125 150 200
Seat 32 40 50 55 55 85 125 130 150
Rated
Cv
EQ% 12 12 17 12   17 30 17 30 50 30 50 80 50 80 125 80 125 180 125 180 265 180 265 470
Linear% 12 12 20 12   20 42 20 42 60 42 60 90 60 90 150 90 125 200 125 200 330 200 330 520
Travel(mm) 25 38 50 75

Globe Control Valve Face to Face Dimension (mm)

 

DN A
Class 150 RF
JIS 10K FF RF
PN16 RF
JIS 16K RF Class 300 RF
JIS 20K RF
JIS 30K RF
PN40
Class 600 RF
JIS 40K RF
PN63
JIS 16K JIS 20K JIS 30K JIS 40K
     32 190 205 210
     40 222 231 235 251 235 236 248 251
     50 254 263 267 286 265 267 276 286
     65 276 288 292 311 290 292 303 311
     80 298 313 317 337 310 317 326 337
    100 352 364 368 394 360 368 379 394
    125 403 425 457 425 457
    150 451 465 473 508 475 473 486 508
    200 543 560 568 610 570 568 580 610
    250 673 708 752
    300 737 775 819
    350 889 927 972
    400 1016 1057 1108
    450 1140 1181 1239
    500 1267 1397 1499
    600 1556 1576 1676

 

DN A
     Class 150
RJ
Class 300
RJ
    Class 600
RJ
Class 300     Class 600 Class 150
SW、BW
   Class 150、600
SW、BW
32  235 248 251 244 248 251 251
40  235 248 251 244 248 251 251
50  267 283 289 276 283 286 286
65  289 308 314 302 308 311 311
80  311 333 340 327 333 337 337
100  365 384 397 378 391 394 394
150  464 489 511 483 505 473 508
200  556 584 613 578 606 568 610

 

DN A
JIS63K Class 900 Class 1500 Class 2500
RF RF(SW,BW) RJ RF(SW,BW) RJ RF(SW,BW) RJ
40 323 333 333 333 333 358 361
50 354 375 378 375 378 400 403
80 431 440 443 460 463 498 504
100 496 510 513 530 533 575 585
150 699 715 718 770 776 820 833
200 895 915 918 972 982 1020 1036
250 1137 1140 1327 1336
300 1311 1314 1400 1416
350 1526 1526
400 1520 1520
450 1720      1720

Selection Based on Operational Conditions

When selecting an electric control valve, consider the operating conditions such as medium type, working pressure, and temperature:

  • Medium Type: The type of medium greatly affects the performance and structure of the valve. Corrosive media require corrosion-resistant materials or protective measures.
  • Working Pressure: Influences the performance and lifespan of the valve. High pressures necessitate high-strength materials and structures.
  • Working Temperature: Affects the materials and sealing performance of the valve. High temperatures require materials and seals that can withstand the heat.

Electric Actuator Basics

  • Power Supply: Options DC24V, AC220V, AC380V.
  • Input Control Signal: Typically 4-20MA or DC1-5V.
  • Feedback Control Signal: Usually DC4-20MA (load resistance under 500 ohms).

Electric control valves receive signals from automation control systems (e.g., 4~20mA) to adjust the valve and control parameters such as flow, temperature, and pressure, enabling automated adjustment.

Flow Characteristics and Selection

Flow characteristics of electric control valves include linear, equal percentage, and parabolic options, each suitable for different applications based on required control precision and stability.

Equal Percentage Characteristics

The relative stroke and flow of the equal percentage characteristic are not linear. This occurs because the flow change at any stroke point is proportional to the flow at that point, and the percentage change in flow remains consistent. As a result, when the flow is small, the change is minimal; when the flow is large, the change is significant, providing the same precision of adjustment at different openings.

Linear Characteristics

The relationship between the relative stroke and flow for linear characteristics is linear. The flow change caused by any unit change in stroke is constant. This means that large flows result in minor relative changes, and small flows result in significant relative changes.

Parabolic/Modified Characteristics

Characteristic Curves Of Control Valve
Characteristic Curves Of Control Valve

THINKTANK offers expert selection advice and free technical support and consultation services. Contact us to optimize your industrial processes with reliable, efficient control solutions.

The Ultimate Valve Cv Sheets

 

 

 

Additional information

Size:

1'' ~ 24''

ANSI Class:

150 ~ 2500LB

Body Materials:

A216 WCB, A216WC6, A352 LCB, A351 CF8, A351 CF8M, A351 CF3M, A351 CF3

Temperature Range:

-196 ~ +550°C

One-time business is not our goal, we pursuit for long-term partner relationships.

ASK FOR A QUOTE

We are not just providing simple quotes but experts in selection, calculation, and drawing. 

Search Related Information

Get an Instant Quote

Avoid your inquiry is delay response, please enter your WhatsApp/Wechat/Skype along with the message, so we can contact you at the very first time.

We will reply you within 24 hours. If for urgent case, please add WhatsApp: +86 185 1656 9221, or WeChat: +86 199 2125 0077. Or call +86 189 5813 8289 directly. 

Get An Instant Quote

Joy Preview

Get An Instant Quote

We will reply you within 24 hours. If for urgent case, please add WhatsApp: +86 199 2125 0077, or WeChat: +86 199 2125 0077. Or call +86 189 5813 8289 directly. 

Direct to Control Valve Factory With Competitive Price & Reliable Quality

Joy Preview
Joy Preview

Get An Instant Quote

Just leave your name, email, and simple message or requirements, We will contact you within 1 hour.

WhatsApp: +86 199 2125 0077

Skype ID: sowell85

Wechat ID: +86 199 2125 0077