Description
HCB Series Balanced Cage Single-Seat Control Valve
The HCB series balanced cage single-seat control valve includes both straight-through and angle types. These valves use high-performance sealing rings on the valve plug or cage. The valve body is compactly structured and equipped with a flow-directing vane designed to enhance the fluid balance around the cage, resulting in minimal pressure drop, high flow capacity, wide adjustability, and precise flow characteristics. This design conforms to the IEC 60534-2-1-2011 standard. The control valve offers excellent dynamic stability, low noise, and minimal cavitation corrosion. It meets the ANSI FCI 70-2-2013 standard for leakage. The valve is compatible with either a multi-spring diaphragm or a cylinder actuator, which provides a compact structure and high output force. The HCB sleeve control valve is suitable for managing various high-temperature and low-temperature high-pressure fluids and can be customized for special requirements.
SPECIFICATIONS
Body type
Straight-through, cast globe valve
Nominal size
3/4’’, 1’’, 1-1/4’’, 1-1/2’’, 2’’, 2-1/2’’, 3’’, 4’’, 5’’, 6’’, 8’’, 10’’, 12’’, 14’’, 16’’
Pressure rating
• ANSI Class 125, 150, 300, 600
• JIS 10K, 16K, 20K, 30K, 40K
• PN1.6, 4.0, 6.4, 10.0 Mpa
End connection
• Flanged End: FF, RF, RJ, LG
According to ANSI B16.5, JIS B2201, JB/T79.1, JB/T79.2
• Welded End: SW, BW
• Threaded End: Threaded, RC, NPT
Material
A216 WCB, A216WC6, A352 LCB, A351 CF8, A351, CF8M, A351 CF3M, A351 CF3
Bonnet type
• Plain bonnet (-17 to 230°C)
• Extension bonnet Type1(-45 to -17°C and 230 to 566°C)
• Extension bonnet Type 2 Cryogenic
Integral cast type (-100 to -45°C)
Welded type (-196 to -100°C)
• Bellows type
Actuator type
Single-acting diaphragm actuator, Spring type piston actuator, Double acting piston actuator
Diaphragm material
Cloth embedded nylon and ethylene propylene rubber
Spring range
• 20 to 100 kPa(0.2 to 1.0 kgf/cm2)
• 40 to 200 kPa(0.4 to 2.0 kgf/cm2)
• 80 to 240 kPa(0.8 to 2.4 kgf/cm2)
Supply pressure
0.14, 0.16, 0.28, 0.4, 0.5 Mpa
Air connection
Rc1/4 or 1/4 NPT internal thread
Ambient temperature
-20 to 70℃
Valve action
• FO: Air to close(Direct action actuator is combined.)
• FC: Air to open(Reverse action actuator is combined.)
Optional accessories
• P/P or I/P Positioner
• Air filter regulator
• Top-mounted or Side-mounted Handwheel
• Limit switch
• Solenoid valve
• Motion transmitter
• Booster relay
• Lock-up valve
• Air lock relay
• Others
Performance
Rated Cv value
Flow characteristics
• Equal percentage
• Linear
Leakage
• Metal Seat
According to ANSI B16.104 Class II, leakage less than 0.5% of maximum valve capacity.
• Soft Seat
According to ANSI B16.104 Class VI, leakage less than 0.00001% of maximum valve capacity.
Inherent rangeability
• 50:1 (Optional 75:1 for full port size)
Hysteresis error
• Without positioner: Within 3% F.S.
• With positioner: Within 1% F.S.
Linearity
Without positioner: Within ±5% F.S.