    What are self-operated pressure regulators?

    dn50 150lb self operated pressure regulator
    dn50 150lb self operated pressure regulator

    The self-actuating pressure regulators are designed to maintain the adjustable setpoint of the pressure reducing system. It can be controlled upstream pressure or downstream pressure and is self-actuating, so no additional auxiliary energy sources such as electricity or air are required. THINKTANK’s ZZY series of self-operating pressure regulators are easy to operate and set up, and these are probably the most cost-effective pressure control valves available.

    SPECIFICATIONS
    Valve Body

    Plug Type Single-Seated(ZZYP), Cage Type(ZZYM), Double-Seated(ZZYN)
    Action Type Control Upstream Pressure(B Type) and Control Downstream Pressure(K Type)
    Nominal Diamter DN15mm ~ 300mm(1/2’’ ~ 16’’)
    Flow Characteristic Quick Open
    Adjusting Accuracy ±3 ~ 10%
    Working Temperature ≤350
    Pressure Reduction Rate Max. 10, Min. 1.25
    Trim Material Standard Material, Working Temperature, Pressure Range and Leakage Information, Please Refer
    to Sheet 1 and Figure 1.
    Nominal Pressure PN1.6MPa, 4.0MPa, 6.3MPa, 10.0MPa, Class 150, 300, 600.
    Connection Type Flanged Ends, Welded Ends, and Threaded Ends.
    Body & Bonnet Material WCB, WC9, CF8, CF8M
    Actuator Type Diaphragm, Piston/Cylinder, Bellows
    Packing PTFE, Flexible Graphite


    Adjusting Pressure Range(kPa)

    15~50, 40~80, 60~100, 80~140, 120~180, 160~220, 200~260, 240~300, 280~350, 330~400, 380~450, 430~500,
    480~560, 540~620, 600~700, 680~800, 780~900, 880~1000, 950~1100, 1080~1250, 1230~1400, 1380~1550,
    1530~1800, 1780~2000, 1980~2300, 2280~2500

    Construction Type

    image 7
    image 8
    image 9
    image 9

    How to operate self-operated pressure regulators? How it works?

    Self-Operated Pressure Regulator Drawing
    self operated regulator

    Here are some physical requirements you should know before the installation of the pressure regulator.

    1. Self-operated pressure regulators are used primarily for steam, non-flammable vapors, and gases.
    2. Pressure range-ability: 1:10
    3. When the work at steam or vapor which a service temperature of over 100°C, it’s necessary to use a sealed tank to protect the diaphragm of the self actuator against overheating.

    Now we know the self-operated pressure regulators are driving by the medium energy without any auxiliary energy. But how it works? Let’s learn deep of this regulator. For example, controlled downstream pressure application.

    The downstream pressure acts on the actuator diaphragm through the control line, where it is converted into a force that reacts to the spring force.

    Through adjustment, the preload force of the spring can be changed so that the two forces are in equilibrium under the required downstream pressure. The steam discharge capacity will cause the corresponding displacement of the valve plug until the equilibrium state is re-established.

    The two stainless steel bellows of the pressure reducer can be seen in above figure.

    One is for the purpose of sealing the main shaft from the outside, and the other below is a pressure relief element, which is used to ensure equal force on the valve plug. For this purpose, upstream pressure is applied to the outside of the bellows from the inside through the hole in the valve plug. The inside of the bellows is connected to the downstream pressure through an orifice. Since the effective area of the bellows is the same as the valve seat area, the pressure difference can be compensated, so that the pressure regulator is basically not affected by upstream pressure fluctuations. In automatic process engineering applications, pressure regulators are classified as proportional controllers. The characteristic of such a controller is that the control deviation from the set value is permanent depending on the following factors: spring preload, nominal diameter, and P2/P1 ratio.

    What’s the difference of pilot-operated valves & direct acting valves?

    Most self-operated pressure regulators currently available can be divided into the following two main types:

    • Direct-acting pressure control valves
    • Pilot-acting pressure control valves

    A direct-operated regulator is the first choice unless the flow or accuracy requirements cannot be satisfied.

    steam the energy fluid
    steam the energy fluid

    Direct-acting pressure control valves can also be used in water, seawater, steam, because the actuator force is provided by the pressure acting on the actuator diaphragm instead of the bellows.
    Therefore, they will cause the upstream or downstream pressure to change with the change of the medium flow rate. Careful consideration should be given when selecting and determining the valve size.

    Pilot-operated pressure control valve works by balancing the downstream pressure between the pressure sensing tube and the pressure regulating control spring. This moves the pilot valve to adjust the control pressure. The control pressure transmitted through the pilot valve is proportional to the opening of the pilot valve and is guided to the lower side of the main valve diaphragm through the control pipe.

    pilot operated pressure regulator
    pilot operated pressure regulator

    Pilot-operated pressure regulator VS. direct-operated pressure regulator

    Accuracy

    The accuracy of the pilot-operated regulator is much higher than that of the direct-acting regulator. Generally, direct-acting regulators need to deviate from the set point by 20%-40%, while pilot-operated regulators need 1%-5%.

    Response time

    The direct-acting regulator has the fastest response speed, because the change in upstream pressure causes the diaphragm to move directly related to the plug stroke. The pilot-operated regulator is subject to the same events, but the load pressure must be changed before the main valve can be repositioned. The loaded pilot valve is a bit faster than the unloaded pilot valve, because the main valve diaphragm can sense the outlet pressure, so that the main valve provides a good start for changes in outlet pressure.

    Capacity

    The pilot-operated regulator can provide a larger size and therefore a larger capacity. Due to its excellent accuracy, the flow capacity of basically all pilot-type regulators can be used, while the effective flow rate of direct-type regulators is limited due to excessive droop.

    Minimum differential pressure required

    There is no minimum differential pressure requirement for direct-operated pressure regulator. Regardless of the pressure difference, they can continue to controlling, but the pilot regulator needs to require a pressure difference between its inlet and outlet in order to open the main valve. The unloading pilot valve has a small diaphragm and requires a higher pressure difference to fully open the main valve.

    Cost of Maintenance

    The direct-acting regulator is the simplest and most compact type of regulator, so it is the least expensive and easiest to maintain. The unloading pilot valve is the next least costly, because their main valve is simple in design, combining the diaphragm and the valve plug into one component, the protective cover.

    Direct-operated regulators are the least complex and most compact of the regulator styles making them the least expensive and easiest to maintain.

    Practical System of Steam Pressure Reducing Station

    steam pressure reducing station
    steam pressure reducing station
    system reqirements

    system reqirements
    image 10
    Installation

    Keywords of self-operated pressure regulators

    There are many terms that can be expressed as pressure regulators. Here we give examples of several terms commonly used by customers。

    • Direct-acting pressure reducing valves
    • Direct-operated regulators
    • Pilot-operated pressure reducing valves
    • Pilot-operated regulators
    • Self-acting pressure control valves
    • Self-operated regulator
    • Self-actuated pressure control valves
    • Large pressure reducing regulator
    • Pressure reducing regulator valve

    For more information, please contact our representative to assistant you. Or, you can email direct via <[email protected]>

    Facebook
    Twitter
    LinkedIn
    Pinterest
    Print
    Picture of Will Don

    Will Don

    After earning my bachelor's degree in mechanical engineering from Zhejiang Normal University in 2008, l was fortunate enough to begin my career with Siemens, Fisher, and YTC, focusing on control valve accessories. Over the past dozen years, l've poured my heart and energy into understanding technology and fluid solutions for control valves.
    Now, as the marketing director for THINKTANK, a trusted branch of the Taiwan STONE valve group, I can't help butf eel proud of how far we've come. Our knowledge isn't just reaching professionals like engineer and valve distributors; it's also inspiring the next generation of automation college students.
    l genuinely hope you're enjoying our articles and finding them helpful.Your thoughts, questions, and feedback mean the world to me, so please don't hesitate to reach out to marketing[at]cncontrolvalve.com. Whether you're a seasoned expert or just curious about the field, I'm here to connect, share, and learn together.

    All Posts »

    I am the author of this article, and also the CEO and marketing director of THINKTANK, with 15 years of experience in the industrial valve industry. If you have any questions, you can contact me at any time.

    Subscribe Now

    Receive the latest product information and industry news.

    We value your privacy. Your information will be kept confidential.

    Contact Us

    Just fill out your name, email address, and a brief description of your inquiry in this form. We will contact you within 24 hours.

    The Latest News
    spring return electric actuated ball valve fail safe

    Spring Return Electric Actuator: Technical Principles, Applications and Common Valve Types

    The Spring Return Electric Actuator is a critical device for ensuring safety in high-risk environments such as tunnels, subways, marine applications, and other areas where ...
    Read More
    pilot operated breather valve

    Case Study: How to Select a Suitable Breather Valve to Handle Back Pressure

    In industrial storage tank applications, it is critical to select the right pressure and vacuum relief valves (PVRV) to ensure the safe operation of the ...
    Read More
    axial piston high pressure pump

    High Pressure Pumps Axial Piston Pumps

    In the past 5 years, we made our HPR/HPH series axial piston pumps as OEM products for a well-known brand. These pumps have been successful ...
    Read More
    breaker valve manufacturer

    VB14 and VB21 Vacuum Breaker Installation

    VB14 Vacuum Breaker Description VB14 is a small special vacuum breakers used in condensing vapour/steam or liquid systems, and it made of Brass material, and ...
    Read More
    common valve abbreviation guide

    Common Valve Abbreviation Guide

    In industrial manufacturing and instrument maintenance, you’ll see many abbreviations for valves. It’s important for engineers, maintenance people, and students to know these abbreviations because ...
    Read More
    spray & fuse coating

    Comprehensive Technical Guide on Hard Coating For Severe Service Valve

    One of the most effective ways to improve the durability and performance of valves in in severe service environments, where valves are work at extreme ...
    Read More
    dosing valve DN100 lime dosing system

    What is a Lime Dosing Valve and How Does It Work

    In the world of water treatment and chemical processing, it’s important to control lime dosing accurately. Getting the pH right and avoiding lime blockages can ...
    Read More
    concentrated solar power schematic

    Selection and Application of Molten Salt Control Valves

    In recent years, as the environmental impact of traditional energy sources such as coal and petrochemicals has become more and more of a concern, there ...
    Read More
    molten salt power system

    Comprehensive Guide of Molten Salt Valve

    In the world of advanced energy systems, molten salt valves are a critical component for controlling high-temperature fluids that are important for storing and transferring ...
    Read More

    Contact Us

    With expertise in valves and rich experience in the oil&gas, chemical industry, textile mills, power plants, and sugar mills. THINKTANK has become the premier manufacturer of next-generation precision control valves.

    With a customer base that includes over 42 of the world’s leading engineering&contractors and international valve brands, THINKTANK Valves offers cost-effective valves that help our customers achieve automated process control without paying high prices.

    Why are more and more international valve brands choosing THINKTANK for OEM service?

    Brand is reputation, which not only requires high valve technology, but also great comercial support and fast response after-sales service and delivery time. They will not gamble their brand on an unknown product

    Get an Instant Quote

    Avoid your inquiry is delay response, please enter your WhatsApp/Wechat/Skype along with the message, so we can contact you at the very first time.

    We will reply you within 24 hours. If for urgent case, please add WhatsApp: +86 185 1656 9221, or WeChat: +86 199 2125 0077. Or call +86 189 5813 8289 directly. 

    Get An Instant Quote

    Joy Preview

    Get An Instant Quote

    We will reply you within 24 hours. If for urgent case, please add WhatsApp: +86 199 2125 0077, or WeChat: +86 199 2125 0077. Or call +86 189 5813 8289 directly. 

    Direct to Control Valve Factory With Competitive Price & Reliable Quality

    Joy Preview
    Joy Preview

    Get An Instant Quote

    Just leave your name, email, and simple message or requirements, We will contact you within 1 hour.

    WhatsApp: +86 199 2125 0077

    Skype ID: sowell85

    Wechat ID: +86 199 2125 0077