Introduction of Control Valves Installation, Operation, and Troubleshooting

Table of Contents
    Add a header to begin generating the table of contents

    The control valve is the final control process in an automatic system. There are pneumatic, electric, hydraulic, and smart digital types of control valves. Utilized in process lines to control the flow of medium, and control valve process according to required settings. It has far-reaching meaning on safe and balanced production. There is an introduction of control valve installation, operation, and maintenance according to the actual production condition.

    The principle and significance of installing control valve:

    a. Safety

    1. Valve leakage prevention: Valve leakage is not allowed in the process of production. During the operating time, it will cause valve leakage if packing and flange gasket part has even small gap or hole. If the operating conditions of liquid medium are very harsh (high temperature, high pressure, corrosive medium), the damage will be more and more serious, and the leakage will be more and more severe. Therefore, the selection of packing, sealing method, pressure reduction, using well-sealing valves are all factors considered by the installation personnel, and are also the basic conditions to prevent valve leakage.

    2. Install vent or discharge valves. Any pipeline design and installation will accumulate high-pressure liquid when it is cut off. If the potential energy of the accumulated fluid is very dangerous, vent or discharge valves should be installed on each side of the control valve. Two vent or discharge valves should be installed on the valve with a large amount of high-pressure materials. A large amount of high-pressure fluid accumulated between the shut-off valves may accumulate considerable force, and serious personal accidents may occur if the operation of releasing the pressure of control valve is careless. After the system is cut off, the pressure can be maintained for a period of time. Keep valve opened will be a safe step to reduce pressure and release harmful fluid. And also choosing a rate limit vent valve can protect the operating stuff. If the fluid containing suspended particles, the vent will be blocked easily, therefore, at the top of pipeline should install bigger size vent valve for safely release.

    3. Safe pipeline: Sand, scale, metal chips and other substances in the pipeline will damage the surface of the control valve and make it not close tightly. Therefore, before installing control valve all the pipeline and fittings should be purged and extremely purified. If the releasing fluid is harmful gas, the vent pipeline should connect to a safe place. Even it is non-flammable gas should release with vent to avoid blowing out the gas with rust or other substance and injury to the operator. If the discharged fluid is a dangerous liquid, connect the vent pipe to a safe container. During operation, the valve may be very hot, and precautions must be taken to prevent scalding the operator. When installing the pipe fittings connected by screws, it is necessary to prevent the sealant from falling into the installation pipeline. Generally, PTFE sealing belt should be used instead of sealant; The steam pipe near the upstream or downstream of the control valve shall be insulated. In the pipeline system with serious pressure fluctuation, pipeline buffer is required.

    b. Utilize performance

    When installing control valve, its performance should not be affected by the dynamic as far as possible. The valve inlet is a straight pipe section, which can stabilize the pressure of the fluid entering the valve. The valve can ensure a stable flow at each opening. Generally, the experience length of the straight pipe section should be 10-20 times of the pipe diameter, and the straight pipe section of the outlet piping should also have enough length. Generally, it is 3-5 times of the pipe diameter. Of course, the longer the pipe section is, the better the performance is. The pressure gauge should be installed at the front and the back of the valve to show whether the pressure is stable. Under actual situation of checking the flow state and system fault, it is conducive to judging the operation characteristics and fault state of the valve, and is conducive to the operators to accurately observe the actual situation and adjust the operation parameters.

    c.  Good installation position, easy access, improve work efficiency, save maintenance costs

    When installing the control valve, it is necessary to consider the on-site maintenance or routine disassembly and maintenance of the control valve. The maintenance cost depends on the convenience of approaching the valve. If it is necessary to disassemble the top bonnet with stem and plug, there should be enough space above the valve. If it is necessary to disassemble the bottom flange and stem, plug bonnets, there should be enough space. If the valve accessories such as handwheel, valve positioner and retaining valve need to be disassembled, the side of the valve should be enough space, and the bolts on the valve body flange should be disassembled with enough space. If the pipeline is vertical and the control valve must be installed horizontally, it is necessary to support the actuator on the pipeline with hook or brace, or support the control valve with v-bolt pipe clamp and support plate, eliminate the effect of thermal expansion.

    d. Manual operation reduces incorrect operation

    The installation position of the valve should be easy to operate. The operator should be able to see the display data of the indicator, the glass level gauge of the tank, and adjust the liquid level manually. He can see the pressure gauge or stem displacement scale of the pipeline. He can use the parameter indicator to make parameter changes. Installing the pipeline valve for manual operation should not affect the flow characteristics of the control valve. The control valve may or may not have a handwheel mechanism, so the bypass valve should be selected according to the situation.

    e. Environment is the guarantee of production balance

    The actuator of shall not be exposed to high temperature environment. When the temperature is higher than 38 ℃, the diaphragm, seal and positioner parts will be obviously affected by high temperature. In places with vibration, the vibration of the pipeline may cause the displacement of the pipeline. Therefore, the gas pipe, hydraulic pipe and electrical end should have enough flexibility, all the connecting lines should avoid water and liquid erosion, and the end of the pipe should be equipped with a connector to discharge the liquid. The simpler the disassembly and assembly, the better.

    The valve positioner, valve position transmitter and limit switch shall be directly installed on the actuator, the quick discharge valve shall be installed on the vent lines of the actuator. The more transmission parts there are, the more likely they are to vibrate. When using electric control valve should pay more attention.

    Common faults of control valve and their elimination

    I. Main failure components of actuator

    1.) Pneumatic and hydraulic actuator)Diaphragm: Under the normal condition of the air supply system, if the actuator can not act, it is the cause of diaphragm rupture and damage. When there are sharp corners, burr, and other defects on the metal contact surface, the diaphragm will be punctured. Another reason is that the diaphragm will be damaged due to material aging and long-time using.

    2.) Piston, pneumatic and hydraulic actuator produces driving force. Due to damage there will be no driving force and will be insufficient due to wear.

    3. ) The air pipe is the channel of input pressure actuator, if the connection is not firm or air leakage will make the input pressure actuator unable to work properly.

    4.) Stem: bending, deformation, falling off, the connection between the push rod and the stem is not firm will cause insufficient travel or valve closed.

    5.) Spring: spring fracture, spring elasticity loss will make the valve can not work properly.

    2. Electric actuator

    1. ) Motor: check the motor can rotate or not, whether it is easy to overheat, whether there is enough torque and coupling force.
    2. ) Servo amplifier: check whether there is output or it can be adjusted.
    3. ) Reduction mechanism: check transmission parts — shaft, gear, and worm gear are damaged or overwearing.
    4. ) Moment of force controller: check for failure.

    II. Main fault components of valve

    1.Body: always check the corrosion and wear condition of the valve wall. Especially the valve used under corrosive medium and high pressure difference process conditions.

    2. Plug: it is a movable closure element, which is easily damaged under high pressure difference and no-load condition due to the erosion, corrosion and particle collision of medium. Therefore, it is necessary to check the damage, abrasion andcorrosion frequently, repair and replace it in time.

    3. Seat: the joint surface of valve seat is the key to ensure the valve to close. Due to the penetration of medium, the internal thread surface of fixed valve seat is often corroded and loosened. Special inspection shall be conducted during maintenance.

    4. Stem: check the connection between valve stem, valve plug, and the stem is loose or not, and whether there is excessive deformation, crack, and corrosion.

    5. Packing: check the tetrafluoroethylene or other packing is aged, deteriorated due to lack of oil, and whether the packing is compacted.

    6. Gasket and O-ring, these vulnerable components are often cracked and aged.

    Facebook
    Twitter
    LinkedIn
    Pinterest
    Print
    Picture of Will Don

    Will Don

    After earning my bachelor's degree in mechanical engineering from Zhejiang Normal University in 2008, l was fortunate enough to begin my career with Siemens, Fisher, and YTC, focusing on control valve accessories. Over the past dozen years, l've poured my heart and energy into understanding technology and fluid solutions for control valves.
    Now, as the marketing director for THINKTANK, a trusted branch of the Taiwan STONE valve group, I can't help butf eel proud of how far we've come. Our knowledge isn't just reaching professionals like engineer and valve distributors; it's also inspiring the next generation of automation college students.
    l genuinely hope you're enjoying our articles and finding them helpful.Your thoughts, questions, and feedback mean the world to me, so please don't hesitate to reach out to marketing[at]cncontrolvalve.com. Whether you're a seasoned expert or just curious about the field, I'm here to connect, share, and learn together.

    All Posts »

    I am the author of this article, and also the CEO and marketing director of THINKTANK, with 15 years of experience in the industrial valve industry. If you have any questions, you can contact me at any time.

    The Latest News
    dubai seawater desalination project

    Passion Like a Beam of Light

    Passion, like a beam of light,Illuminates every ordinary soulWho strives with earnest toil,Rendering life brilliantly meaningful,With not a moment spent in vain,Defining the essence of ...
    Read More
    dn25 pn16 wcb pcv (1)

    Pneumatic Single-Seat Globe Control Valves PCV DN25 PN16

    DN25 PN16 A216GR.WCB PCV (THINKTANK)
    Read More
    heat shutdown on off valve

    Valvula shut off com atuador fusível

    A válvula shut-off com atuador fusível é um dispositivo utilizado para controlar automaticamente o fluxo de fluidos em tubulações, especialmente em situações de emergência ou ...
    Read More
    c95500 nickel aluminum bronze control valve factory thinktank

    Engineering Case Studies of C95500 Nickel Aluminum Bronze Control Valves

    In modern industry, the choice of control valves is critical for ensuring the reliability, efficiency, and safety of processes. As a leading manufacturer of C95500 ...
    Read More
    atex ped certificate

    Congratulations to THINKTANK Achieve ATEX and PED Certificates For Fusible Link Safety Valve and Breather Valve Series

    As the co-founder of THINKTANK, it is with a profound sense of pride and humble excitement that I share a milestone that marks a significant ...
    Read More
    Self Operated Pressure Regulator

    The 18inch Self-Operated Pressure Regulator Super Duplex 2507

    The DN450(18″) 150LB self-operated pressure regulator is made from super duplex 2507 material. This pressure regulator is specifically designed for seawater desalination applications, where exceptional ...
    Read More
    canary bridge data centre phase 39

    THINKTANK Delivers 898 Ball Valves Ahead of Schedule to Malaysia

    THINKTANK has advanced the delivery of 898 ball valves to a Malaysian client, with all valves undergoing 100% rigorous testing to ensure a 100% qualification ...
    Read More
    thinktank control valve factory

    Top 10 Industrial Valve Manufacturers in China 2024

    This article is not just aimed at keeping international brands informed about the latest developments in the Chinese industrial valve industry but also serves industrial ...
    Read More
    flow conversion table

    Fluid Flow Rate Conversion Chart

    Flow rate measures the volume of fluid that passes through a specific point within a given time frame, commonly used units include cubic meters per ...
    Read More

    Contact Us

    With expertise in valves and rich experience in the oil&gas, chemical industry, textile mills, power plants, and sugar mills. THINKTANK has become the premier manufacturer of next-generation precision control valves.

    With a customer base that includes over 42 of the world’s leading engineering&contractors and international valve brands, THINKTANK Valves offers cost-effective valves that help our customers achieve automated process control without paying high prices.

    Why are more and more international valve brands choosing THINKTANK for OEM service?

    Brand is reputation, which not only requires high valve technology, but also great comercial support and fast response after-sales service and delivery time. They will not gamble their brand on an unknown product

    Get An Instant Quote

    Joy Preview

    Focused on Control Valves & Self-Operated Pressure Regulators For Over 30 Years

    A Good Partner Is A Lasting And Effective Investment

    Get An Instant Quote

    Direct to Control Valve Factory With Competitive Price & Reliable Quality

    Joy Preview
    Joy Preview

    Get An Instant Quote

    Just leave your name, email, and simple message or requirements, We will contact you within 1 hour.

    WhatsApp: +86 185 1656 9221

    Skype ID: sowell85

    Wechat ID: +86 199 2125 0077